UPS5000-E-(30-120KVA)-G
UPS5000-E-(30-120KVA)-G
UPS5000-E- (30-120kVA) -G is based on online dual transformation technology, which is mainly used in small and medium-sized enterprise data centers, large enterprise regional headquarters central computer rooms, control centers, security computer rooms, automatic control systems, precision instruments and equipment and other scenarios. The modular architecture is adopted, and the availability is greatly improved. The easy-to-use and efficient design can effectively reduce engineering costs and operation and maintenance costs.
Technical Specification

Model number

UPS5000-E-30KVA-G

UPS5000-E-60KVA)-G

UPS5000-E-90KVA-G

UPS5000-E-120KVA-G

Rated capacity (kVA/kW)

30KVA/30kW

60KVA/60kW

90KVA/90kW

120KVA/120kW

Number of power modules

1

2

3

4

Main Road input

Input format

3Ph+N+PE

Rated input voltage

380/400/415VAC

Input voltage range

138 to 485VAC

 (305 to 485VAC without derating, 305 to 138VAC linear derating to 40%)

Input frequency range

40 to 70Hz

Current Total Harmonic Distortion (THDi)

<3% (linear full load)

Input power factor

0.99

Bypass input

Input format

3Ph+N+PE

Rated input voltage

380/400/415VAC

Bypass frequency range

50/60±6Hz

Battery

Rated input voltage

360 ~ 528VDC(lead-acid battery: 30~44, adjustable battery number, default 40) 512VDC (SmartLi)

The output

Output format

3Ph+N+PE

Rated voltage

380/400/415V AC±1%

Output frequency

Synchronization state, tracking the bypass input (online); 50/60Hz±0.05% (battery mode)

Voltage Harmonic distortion (THDv)

< 1% @ 100% linear load

Overload capacity

105%< load ≤110%, switch to bypass after 60 minutes;

When 110%< load ≤125%, bypass after 10 minutes;

125%< load ≤150%, bypass after 1 minute;

When load >150%, bypass after 200 ms;

system

Wiring methods

Up and down into the line compatible *

Switch

690VAC 250A/3P

 (maintenance bypass, main, static bypass input switch, output switch)

Output power factor

1

System efficiency

Up to 96% *

Parallel capability

4 PCS

Redundant power modules

N+1 redundancy is supported

Environment

Operating temperature

0 ℃ to 40 ℃

Storage temperature

- 40 ℃ ~ 70 ℃

Relative humidity

0% to 95% (no condensation)

Working altitude

No derating within 1000m above sea level. Derating above 1000m refers to IEC62040-3 standard, up to 4000m

Noise

64.5 dB

Other

Height x width x depth (mm)

2000mm×600mm×850mm

Weight

250kg

270kg

290kg                      310kg

Standards and Certification

Standard: IEC62040, YD/T 2165; Certification: Theil, CQC, CE, CB, RoHS, REACH, WEEE, etc

Communication interface

Interface: dry contact, RS485, FE; Communication protocol: HTTPS, Modbus, SNMP


* The descriptions and information displayed in the product promotional materials are for reference only. The actual delivered product shall prevail. The final interpretation right belongs to GLORY.