UPS5000-H- (400K~600KVA)-G
UPS5000-H- (400K~600KVA)-G
UPS5000-H- (400K~600KVA)-G is a new generation of medium and large scale uninteruptable power system, which is mainly used in medium-sized enterprise data centers, large enterprise regional headquarters central computer rooms, automatic control systems, precision instruments and equipment and other scenes. The new 100KVA/3U hot-plug power module is adopted, which can effectively save the floor area and installation time. The system efficiency is as high as 97%. The sleep mode is low-load and efficient. Intelligent online mode to achieve 99.1% ultra-high efficiency, excellent indicators, while ensuring 0ms full mode switching.
Technical Specification

Input format

Three phase four wire +PE

Input the rated voltage

380V AC/400V AC/415V AC (line voltage)

Input voltage range

80V AC ~ 280V AC (phase voltage)

Input rated frequency

50Hz/60Hz

Input frequency range

40Hz to 70Hz

Input power factor

Full load > 0.99

Half load > 0.98

Input harmonic current

THDi ≤ 3% (linear full load)

THDi ≤ 5% (nonlinear full load)

Battery voltage

Lead-acid battery: 360V DC ~ 600V DC

12V battery, 30 to 50 units optional, default 40 units

Max. 12 units connected in parallel

SmartLi: 512V

Battery management

Smart Battery Management

One-click cold start

In the event of a mains power outage, the power from the battery alone is able to start the UPS to power the load

Charger Output Power

The maximum charging power of a single module is 15kW under rated conditions

Charger current limit

Maximum 30A per module

Battery pack sharing function

It supports the battery pack sharing when the power units are connected in parallel, and the default is not to share the battery

Charging voltage requirements

Average charging voltage: 2.3V/Cell ~ 2.4V/Cell, default 2.35V/Cell

Floating charging voltage: 2.23V/Cell ~ 2.3V/Cell, default 2.25V/cell

Minimum voltage of battery cell

1.67V/cell ~ 1.9V/cell

Output mode

Three phase four wire +PE

Output voltage

380V AC/400V AC/415V AC (line voltage)

Output frequency

Synchronizing state, tracking bypass input (mains mode)

50Hz/60Hz±0.05% (battery mode)

Output voltage distortion

THDv ≤ 1% under 100% linear load

THDv ≤ 3% under 100% nonlinear load

Output power factor

1

Unbalanced output voltage

Voltage imbalance: ±3%; Phase unbalance: ±2°

Output overload capability

Inverter overload capacity:

100% < load ≤110%, after 60 minutes to bypass output; 

110% < load ≤125%, 10 minutes after the bypass output; 

125% < load ≤150%, 1 minute after the bypass output