UPS5000-H- (400K~1600KVA)-G
UPS5000-H- (400K~1600KVA)-G
UPS5000-G is a new generation of large and medium uninteruptable power supply system, which is mainly used in medium-sized enterprise data centers, large enterprise regional headquarters central computer rooms, automatic control systems, precision instruments and equipment and other scenes. Using a new 100kVA/3U hot-plug power module, - cabinet - megawatt, effectively saving floor space and installation time, system efficiency up to 97%, low load and high efficiency sleep mode, iPower intelligent means to improve system reliability, simplify operation and maintenance, Intelligent online mode to achieve 99.1% ultra-high efficiency, excellent indicators, while ensuring 0ms full mode switching.
Technical Specification

Model number

UPS5000-H-400/500/600k-N-GT

UPS5000-H-

800k-NT-G

UPS5000-H-

1200k-NT-G

UPS5000-H-

1600k-NT-G

Capacity

Rack capacity

400/500/600kVA

800kVA

1200kVA

1600kVA

Number of modules

2-4/2-5/2-6

2-8 

2-12

2-16

 

 

 

Main road input

Input format

3Ph+N+PE

Rated voltage

380/400/415Vac

Voltage range

138-485V (100% load: 323-485V)

Frequency range

40-70Hz

THDi

Normal mode: Linear full load THDi<3%

Smart online mode: linear full load THDi<3%

Input power factor

Normal mode: 0.99

Smart Online mode: 0.99

 

Bypass input

Input format

3Ph+N+PE

Rated voltage

380/400/415Vac

Input frequency

50/60±6Hz

 

 

Batteries

Rated voltage

360-600Vdc, 30-50 optional, rated at 40, no center line battery, support odd number (lead-acid battery) 512Vdc (SmartLi)

Battery pack sharing

Support (SmartLi, lead acid battery)

Max Max charging power rate/current

Single power module 15%/30A

Battery Pack type

SmartLi, lead acid battery

 

 

Output

Output format

3Ph+N+PE

Voltage

380/400/415Vac±1%

Frequency

Tracking bypass (inverter powered), 50/60Hz±0.05% (battery mode)

THDv

Linear full load THDv<1%

Inverter overload capability

100% < load ≤110%, after 60 minutes to bypass output; 110% < load ≤125%, 10 minutes after the bypass output;

125% < load ≤150%, 1 minute after the bypass output

 

 

 

System

Output power factor

1

Efficiency

Normal mode: up to 97%; Smart online mode: up to 99.1%

Joint Power supply

Support joint power supply of mains and battery

Maximum number of parallel machines

6

4

4

2

Top copper row connection

/

/

Support

Support

Disconnector switch

/

 

 

Environment

Operating temperature

0 C ~ 55 C ( 0℃ ~40℃ without derating; 41℃ ~45℃ derated to 0.9; 46℃ ~50℃ derated to 0.8; And 51℃ to 55℃ to 0.7)

Storage temperature

- 40-70 ℃

Humidity

0%-95% (no condensation)

Running height

0-2000m, above 2000m refer to EN/IEC 62040-3 derating

 

 

Others

Weight (kg)

690/745/800

1300

1600

2300

High x wide x deep

2000mm × 800mm × 1000mm

2000mm × 1600mm × 1000mm

2200mm × 1600mm × 1000mm

2200mm × 2400mm × 1000mm

Standards and Certification

Standards: EN/IEC 62040-1,, EN/IEC 62040-2, EN/IEC 62040-3; ;

Certification: CE, CB, RoHS, REACH, WEEE, etc

Communication interface and protocol

Communication interface: dry contact, RS485, FE; Communication protocol: Web, ModBus, SNMP



Model number

UPS5000-H-400/500/600k-FT-G

Capacity

Rack capacity

400/500/600kVA

Number of modules

2-4/2-5/2-6

 

 

 

 

Main road input

Input format

3Ph+N+PE

Rated voltage

380/400/415Vac

Voltage range

138-485V (100% load: 323-485V)

Frequency range

40-70Hz

THDi

Normal mode: Linear full load THDi<3%

Smart online mode: linear full load THDi<3%

Input power factor

Normal mode: 0.99

Smart Online mode: 0.99

 

Bypass input

Input format

3Ph+N+PE

Rated voltage

380/400/415Vac

Input frequency

50/60±6Hz

 

 

Batteries

Rated voltage

360-600Vdc, 30-50 optional, rated at 40, no center line battery, support odd number (lead-acid battery) 512Vdc (SmartLi)

Battery pack sharing

Support (SmartLi, lead acid battery)

Max Max charging power/current

Single power module 15%/30A

Battery Pack type

SmartLi, lead acid battery

 

 

Output

Output format

3Ph+N+PE

Voltage

380/400/415Vac±1%

Frequency

Tracking bypass (inverter powered), 50/60Hz±0.05% (battery mode)

THDv

Linear full load THDv<1%

Inverter overload capability

100% < load ≤110%, after 60 minutes to bypass output;

110% < load ≤125%, 10 minutes after the bypass output;

125% < load ≤150%, 1 minute after the bypass output

 

 

System

Output power factor

1

Efficiency

Normal mode: up to 97%; Smart online mode: up to 99.1%

Joint Power supply

Support joint power supply of mains and battery

Maximum number of parallel machines

6

Disconnector switch

Built-in switch (main input, bypass input, output, maintenance bypass)

Switch Specifications

690VAC 1250A/3P disconnector switch

 

 

Environment

Operating temperature

 

0℃ ~ 55℃0℃ ~40℃ without derating; 41℃ ~45℃ derated to 0.9;

46℃ ~50℃ derated to 0.8; And 51℃ to 55℃ to 0.7

Storage temperature

- 40-70 ℃

Humidity

0%-95% (no condensation)

Running height

0-2000m, above 2000m refer to EN/IEC 62040-3 derating

 

 

Others

Weight (kg)

750/805/860

Model (height x width x depth)

2000mm × 800mm × 1000mm

Standards and Certification

Standards: EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3; Certification: CE, CB, RoHS, REACH, WEEE, etc

Communication interface and protocol

Communication interface: dry contact, RS485, FE; Communication protocol: Web, ModBus, SNMP


* The descriptions and information displayed in the product promotional materials are for reference only. The actual delivered product shall prevail. The final interpretation right belongs to GLORY.