CloudEngine
S16700-G series
Campus Switch
CloudEngine S16700-G series
CloudEngine S16700-G series flagship core switch is a new generation of flagship frame core switch for high-end campus network. It is committed to improving user network experience, reducing customer network operation costs, and building a safe and reliable campus network.
Technical Specification

Parameters

CloudEngine S16700-4-G

CloudEngine S16700-8-G

Dimensions

(W x d x H, excluding packing material)

483 mm ×985 mm × 438 mm

(Includes hangers and routing teeth, etc.)

483 mm × 985 mm × 703 mm

Case height [U]

9.8

15.8

Weight (empty, excluding packing material) [kg]

94.1 (AC input)

129.8 (AC input)

98.1 (DC input)

135.8 (DC input)

Exchange capacity

952/2876 Tbps

1904/5752 Tbps

Packet forwarding ratio

230400 Mpps

460800 Mpps

Master board slots

2

2

Business board slots

4

8

Swap net board slots

6 (extendable to 9 in the future)

6 (Extensible to 9 in the future)

Number of fan modules

3

3

System power supply

6, support dual source input power supply

10, support dual source input power supply

Redundant main control board

1:01

1:01

Swap board redundancy

N+M

N+M

Power redundancy

Dual input power supply system: N+1 backup is recommended

Dual input power supply system: N+1 backup is recommended

Single input power supply system: N+1 backup considering reliability, double input power supply is recommended

Single input power supply system: N+1 backup considering reliability, double input power supply is recommended

Fan redundancy

The fan module supports thermal backup. Under normal temperature conditions, after the failure of a single fan module, the system supports normal work in a short period of time, but it is recommended to replace the faulty fan module immediately.

The fan module supports thermal backup. Under normal temperature conditions, after the failure of a single fan module, the system supports normal work in a short period of time, but it is recommended to replace the faulty fan module immediately.

Maximum power consumption [W]

4664W

8260W

Maximum power supply capacity of the whole machine [W]

Ac input:

Ac input:

5+1 backup: 3000W×5= 15000W

9+1 backup: 3000W×9= 27000W

6+0 backup: 3000W×6= 18000W

10+0 backup: 3000W×10= 30000W

Dc input:

Dc input:

5+1 backup: 2200W×5=11000W

9+1 backup: 2200W×9=19800W

6+0 backup: 2200W×6=13200W

10+0 backup: 2200W×10=22000W

Heat dissipation method

Exhaust heat dissipation, front and rear air ducts

Ventilation and heat dissipation, front and rear air ducts

* The descriptions and information displayed in the product promotional materials are for reference only. The actual delivered product shall prevail. The final interpretation right belongs to GLORY.