CloudEngine S5735I-L-V2-G series switch is a new generation wide temperature switch, which can provide flexible full gigabit access and 10GE uplink port, support ultra-wide operating temperature range and professional outdoor lightning protection, and can adapt to harsh outdoor cabinet environment. It can be widely used in ultra-wide operating temperature scenarios such as safe city and ETTx.
Technical Specification

Appearance

Description

CloudEngine S5735I-S8T4SN-V2-G

8 x 10/100/1000BASE-T Ethernet ports, 4 GE SFP, 1 DI/DO port, 1 RS485 ports

DC power supply or AC adapter

Packet forwarding rate: 102Mpps

Switching capacity: 520Gbps/ 5.2Tbps


CloudEngine S5735I-S8T4XN-V2-G

8 x 10/100/1000BASE-T Ethernet ports, 4 GE/10GE SFP+, 1 DI/DO Port, 1 RS485 port

DC powered or AC adapter powered

Packet forwarding rate: 102Mpps

Switching capacity: 520Gbps/ 5.2Tbps

CloudEngine S5735I-S8U4XN-V2-G

8 x 10/100/1000BASE-T Ethernet ports, 4 GE/10GE SFP+, 1 DI/DO Port, 1 RS485 port

DC powered or AC adapter powered

PoE++

Packet forwarding ratio: 102Mpps

Switching capacity: 520Gbps/ 5.2Tbps

CloudEngine S5735I-S8U2XN-V2-G

8 x 10/100/1000BASE-T Ethernet ports, 2 GE/10GE SFP+, 1 DI/DO mouth

DC powered or AC adapter powered

PoE++

Packet forwarding ratio: 57Mpps

Switching capacity: 520Gbps/ 5.2Tbps

CloudEngine S5735I-S16T2S4XN-V2-G

16 x 10/100/1000BASE-T Ethernet ports, 2 100/1000M SFPS, 4 GE/10GE SFP+, 1 DI/DO port

DC powered or AC adapter powered

Packet forwarding rate: 117Mpps

Switching capacity: 520Gbps/ 5.2Tbps

CloudEngine S5735I-S8T8P2S4XN-V2-G

8 x 10/100/1000BASE-T Ethernet ports, 8 10/100/1000BASE-T Ethernet ports (PoE+), 2 100/1000M SFP, 4 GE/10GE SFP+, 1 DI/DO port

DC powered or AC adapter powered

PoE+

Packet forwarding ratio: 117Mpps

Switching capacity: 520Gbps/ 5.2Tbps



Parameters

S5735I- S8T4SN-V2-G

S5735I- S8T4XN-V2-G

S5735I- S8U4XN-V2-G

Fixed port

8 x 10/100/1000BASE-T Ethernet ports, 4 GE SFP, 1 DI/DO port, 1 RS485 port

8 x 10/100/1000BASE-T Ethernet ports, 4 GE/10GE SFP+

8 x 10/100/1000BASE-T Ethernet ports, Po ++, 4 GE/10GE SFP+

Fixed serial port

1 way RS485 port

Alarm port

1 way DI/DO port

Case dimensions

(W x D x H)

46mm × 133mm × 150mm

86mm × 133mm × 150mm

86mm × 133mm × 150mm

Installation method

DIN rail installation

DIN rail mount

DIN rail mount

Complete machine weight (including packing material)

1.23 kg

2.11 kg

2.21 kg

IP protection class

IP41

IP41

IP41

Power supply type

60W AC power adapter or external

60W AC power adapter or external

240W AC PoE power adapter or external DC power supply, support 1:1 hot standby

DC power supply, support 1:1 hot standby

DC power supply with 1:1 hot standby support

Rated voltage

DC input: 12~ 48V DC

DC input: 12 to 48V DC

DC input: 56V DC

Maximum voltage

DC input: 9.6~ 60V DC

DC input: 9.6~ 60V DC

DC input: 54 to 57V DC (PoE/PoE+/ POE+ + support) or 48V DC (PoE support)

Maximum power consumption

18.59 W

20.35 W

Without PoE: 21.7W

With PoE: 421.7W (PoE: 400W) *

Long-term operating temperature

0m ~ 1800m altitude, supporting industrial grade optical module:

-40°C ~ +60°C (installed in a sealed cabinet)

-40°C ~ +70°C (installed in a fencer with a ventilation speed of at least 80LFM (Line Feet Minute))

-40°C ~ +75°C (installed in a fencer with its own fan, Ventilation speed of at least 200LFM)

0m ~ 1800m altitude, supporting industrial grade optical module:

-40°C ~ +65°C (installed in a sealed cabinet)

-40°C ~ +70°C (installed in a fencer with a ventilation speed of at least 80LFM (Line Feet Minute))

-40°C ~ +75°C (installed in a fencer with its own fan, Ventilation speed of at least 200LFM)

0m ~ 1800m altitude, supporting industrial grade optical module:

-40°C ~ +60°C (installed in a sealed cabinet)

-40°C ~ +70°C (installed in a fencer with a ventilation speed of at least 80LFM (Line Feet Minute))

-40°C ~ +75°C (installed in a fencer with its own fan, Ventilation speed of at least 200LFM)

Short-term operating temperature

-40°C to +85°C

-40°C to +85°C

-40°C to +85°C

Storage temperature

-40°C to +85°C

-40°C to +85°C

-40°C to +85°C

Lightning protection at the operating port

Common mode ±7kV

±7kV common mode

±7kV common mode

Power port lightning protection

DC power port: differential mode ±1kV, common mode ±2kV

DC power port: differential mode ±1kV, common mode ±2kV

DC power port: differential mode ±1kV, common mode ±2kV

Heat dissipation mode

Natural heat dissipation, no fan

Natural heat dissipation, no fan

Natural heat dissipation, no fan



Projects

S5735I- S8U2XN-V2-G

S5735I- S16T2S4XN-V2-G

S5735I- S8T8P2S4XN-V2-G

Fixed port

8 x 10/100/1000BASE-T Ethernet ports, PoE++, 2 GE/10GE SFP+

16 x 10/100/1000BASE-T Ethernet ports, 2 x 100/1000M SFP, 4 GE/10GE SFP+

8 x 10/100/1000BASE-T Ethernet ports, 8 x 10/100/1000BASE-T Ethernet ports (PoE+), 2 x 100/1000M SFP, 4 GE/10GE SFP+

Alarm port

1 way DI/DO port

Case dimensions

(W x D x H)

44mm × 133mm × 150mm

127mm × 133mm × 150mm

127mm × 133mm × 150mm

Installation method

DIN rail installation

DIN rail mount

DIN rail mount

Complete machine weight(including packing material)

1.3 kg

3.02 kg

3.07 kg

IP protection class

IP41

IP41

IP41

Power supply type

240W AC PoE power adapter or external DC power supply, support 1:1 hot standby

60W AC power adapter or external

240W AC PoE power adapter or external DC power supply, support 1:1 hot standby

DC power supply, support 1:1 hot standby

Rated voltage

DC input: 56V DC

DC input: 12 to 48V DC

DC input: 56V DC

Maximum voltage

DC input: 54 to 57V DC (PoE/PoE+/ POE+ + support) or 48V DC (PoE support)

DC input: 9.6 to 60V DC

DC input: 54 to 57V DC (PoE/PoE+ supported) or 48V DC (PoE supported)

Maximum power consumption

Without PoE: 18.3W

31.3W @10.8V

Without PoE: 29.3W

With PoE: 265W (PoE: 240W)

27.5W @48V

PoE: 279.5W (PoE: 240W)

Long-term operating temperature

0m ~ 1800m altitude, supporting industrial grade optical module: -40°C ~ +60°C (installed in a sealed cabinet)

-40°C ~ +70°C (installed in a fencer with a ventilation speed of at least 80LFM (Line Feet Minute))

-40°C ~ +75°C (installed in a fencer with its own fan, Ventilation speed of at least 200LFM)


0m ~ 1800m altitude, supporting industrial grade optical module: -40°C ~ +60°C (installed in a sealed cabinet)

-40°C ~ +70°C (installed in a fencer with a ventilation speed of at least 80LFM (Line Feet Minute))

-40°C ~ +75°C (installed in a fencer with its own fan, Ventilation speed of at least 200LFM)

0m ~ 1800m altitude, supporting industrial grade optical module: -40°C ~ +60°C (installed in a sealed cabinet)

-40°C ~ +70°C (installed in a fencer with a ventilation speed of at least 80LFM (Line Feet Minute))

-40°C ~ +75°C (installed in a fencer with its own fan, Ventilation speed of at least 200LFM)

Equipment at low voltage input has the following restrictions:

(1) The voltage input is 24V-48V, the ambient temperature is less than or equal to 65℃ (installed in the sealed cabinet), the device supports the use of up to 2 optical modules

(2) the voltage input is 10.8V-60V, the ambient temperature is less than or equal to 60℃ (installed in the sealed cabinet)

(3) The voltage input is 9.6V-10.8V, the ambient temperature is less than or equal to 60℃ (installed in the sealed cabinet), and the equipment supports the use of up to 2 optical modules

Note:

(1) The maximum PoE available power is 240W: the ambient temperature is less than or equal to 60 ° C (installed in the sealed cabinet), the device supports the use of up to 4 optical modules

(2) The maximum PoE available power is 180W: The maximum PoE available power is 240W: the ambient temperature is less than or equal to 60 ° C (installed in the sealed cabinet), the device supports the use of up to 6 optical modules.

(3) The maximum POE available power is 240W: the ambient temperature is less than or equal to 55 ° C (installed in the sealed cabinet), the device supports the use of up to 6 optical modules

Storage temperature

-40°C to +85°C

-40 ° C to +85 ° C

-40°C to +85°C

Lightning protection at the operating port

Common mode ±6kV

±6kV common mode

±6kV common mode

Power port lightning protection

DC power port: differential mode ±2kV, common mode ±4kV

DC power port: differential mode ±1kV, common mode ±2kV

DC power port: differential mode ±1kV, common mode ±2kV

Heat dissipation mode

Natural heat dissipation, no fan

Natural heat dissipation, no fan

Natural heat dissipation, no fan

Method of heat dissipation

Natural heat dissipation, no fan

Natural heat dissipation, no fan

Natural heat dissipation, no fan


* The descriptions and information displayed in the product promotional materials are for reference only. The actual delivered product shall prevail. The final interpretation right belongs to GLORY.